A twin wall insulated chimney system designed for wood burning stoves and multi fuel stove installations. 1) Start your system with a length of Single Wall, Vitreous Enamel Stove Pipe in the same diameter as the outlet on the stove. NFPA has set these standards: —A ventilated type 24-gauge metal thimble must be at least 12 inches larger in diameter than the stove pipe. You can fill the gap between the Twin Wall Pipe and the Wall Sleeve with rockwool but most keep this gap clear. Conservatories are very popular places to install stoves. A sweep will use your new hole to sweep your chimney (you must sweep the chimney before inserting a liner see CHIMNEYS AND LINERS). MASSIVE STOVE DEMAND SO PHONES OFTEN GO TO ANSAPHONE (VERY SORRY). Therefore, in a typical two storey home, you shall require 4 Ventilated Fire Stop Plates and 2 Joist Supports. This guide has been produced by the BFCMA to provide advice and general guidance on the selection and installation of chimneys and flues for maximum performance, safety and durability. 61 sold. The only exception to this rule is for DEFRA approved stoves. 2) Connect a Single to Twin Wall Adapter to convert from this Single Wall Pipe to insulated Twin Wall Pipe a minimum of 150mm before … Continue reading "How to install a wood stove chimney through a wall or roof … of flues and chimneys for wood burning and multi fuel appliances in residential properties. Ventilated Ceiling Plates (or Ventilated Fire Stop Plates) are only four use where a flue system is passing through a ceiling, exiting one living space and entering another above. 7) For internal systems, a Roof Support, Silicone Flashing and Storm Collar are necessary for safely passing through any roof type. For safety, the single- or double-wall … Wood stoves are one way home and property owners keep a house toasty during chillier winter months. My twinwall flue is going through a wall. However, Flashings do not need to be confusing as they basically fall into one of only two categories; either suitable for a tiled/slate roof or not. You can use a spirit level with a 45 degree setting to get your flue pipe angle. And why ventilated plates? The crucial building regulation to consider at this point regards the internal diameter of your flue system. Flashings for tiled roofs have a large base which needs to be secured underneath the tiles whereas Flashings for every other roof type (flat, corrugated, wooden etc.) 58 sold. This way there is a free flow of gasses from the flue. Accordingly, the … Continue reading "Twin wall flue pipe installation guide" has a small base designed to be secured on top of the roof surface. (not horizontally)? Thanks. £10.71 to £149.43. Install Stove Pipe, Chimney Pipe and Chimney Kits and more - Discount Chimney Supply, Inc. Stove pipe is used to make a final interior connection between the chimney or chimney kit to the appliance. Stovesonline can design, plan, specify, supply and support fitting I wide range of lead, nu lead, alu based or EPDM flashing to enable leak proof and watertight joins between your flue system, chimney and roof. This does not pose an issue for chimneys on two storey homes but must be considered for shorter installs such as conservatories and summer houses. Here is my video, How to install Chimney Pipe through the wall for a Wood Burning Stove. If you are installing a wood burning stove, boiler or gas appliance and you are planning to run your flue system either through a wall, a floor or externally you will need to use a twin wall flue system. You will need to match your stove pipe diameter with the diameter of the flue size on your wood burning stove. Chimneys and flues are also available in a number of different materials – stainless steel, concrete, pumice, clay or ceramic and plastic. 3) The remainder of the flue system must be in insulated Twin Wall Flue Pipes only from this point onwards. It may be that the incorrect plaster has been used and you are not allowing for the thermal expansion and contraction of that pipe. Twin Wall Flue Pipe. In order to do that you need a chimney with a good draw. Should you find you have other obstructions then the chimney will need to be re-sited unfortunately. Twin wall flue pipe cannot be cut to length by you to make it fit (although there are adjustable lengths) and one therefore needs to plan carefully when installing a twin wall flue chimney. DuraVent 6" Inner Diameter - DVL Stove Pipe - Double Wall - Close Clearance Kit Includes Adapter, (2) 24" Stove Pipe and (1) 12" Adjustable Pipe Model: 6DVL-KVP $226.23 25mm compressed rockwool insulation. Buy Twin Wall Insulated Flue Pipe Chimney Systems - suitable for wood-burning and multi-fuel stoves. ... relining work comprising the creation of new flue walls by the insertion of new linings such as rigid or flexible prefabricated components. When it comes to the compatibility of Twin Wall, you must stay within the same brand I am afraid and so this Convesa H-Cowl will not connect to a Dinak flue system. 125mm internal diameter. The building regulations concerning offsets and turns in a system states the distance travelling in the offset must not exceed 20% of the overall length of the system. 01559 362847 One of the most frequent questions we are asked by people who are interested in installing a wood-burning stove in a conservatory is: can you have a woodburner flue running through a polycarbonate roof?. FAST & FREE. Planning a brand new flue system may seem daunting at first but with this guide we hope to remove the mystery of creating a twin wall installation to suit your home, avoid the common pitfalls and understand Approved Document J of the building regulations in language we can all understand (highlighted in bold). 175mm outter diameter. You must convert from Single Wall Pipe to your Twin Wall a minimum of 150mm from the underside of that ceiling. Shopping Cart by Shopify. You can also use fire rope but you’ll use a lot of it. Your stove clearance can depend on where you live, whether your … 5” to 5”) you require a Single to Twin Wall Adapter and to increase the diameter (i.e. The hole created for that can then be tidied up with a Rosette Collar. I want to go from 7″ vitreous to 7″ twin wall as high up before the ceiling as possible (it goes into loft space) – any idea how I can do it? 01559 362847 The best wall shields help to radiate the heat from the stove into the room. You can then mortar up the hole and stick your rosette to the wall (using thin lines of Silicon). By keeping the gases within the flue warm, this encourages the draw to continue rising and prevents cooler air outside from negatively affecting this. i don't know how to make a diagram. Free postage. As the name suggests, these pipes feature separate inner and outer skins with a layer of insulation between to prevent heat transfer to the outer edge of the pipe, making them safe to run through any surface type and compliant with Approved Document J of the current Building Regulations. Thanks very much for your enquiry. a wooden structure, you must allow for a safe clearance all the way around the flue of 60mm although this does vary depending on the brand of Twin Wall used). if suitable shielding is installed either on the pipe or on the combustible surface. Quite often, this is only 50-80mm between outer wall surface and the pipe for aesthetic purposes and use with the shortest (and cheapest) Wall Brackets. It is now time to pass the Twin Wall flue through the roof surface itself and there are three important stages to this: Firstly, remember there is a safe clearance to combustible materials that must be maintained around all twin wall flue and so a 6” Twin Wall pipe will require a hole measuring approx. In this article, we will answer that question for you. Sometimes sold as a ‘Fire Stop Spacer’, Ventilated Fire Stop Plates must be secured into the ceiling or the floor whenever the system exits and/or enters a habited space. The minimum clearance may be reduced by 50 percent to 225 mm (9 in.) The structure of the flat roof is wood (combustible!) How To Install Wood Stove Pipe Through Wall. When installed correctly, a flue pipe will not have more than 3 m (10 feet) of straight-run pipe and more than two 90-degree elbows, and will connect to a double- or triple-wall … Most likely yes. Proper sealing is very important to ensure that heat exhaust is vented out of the home and not collecting inside the home or on the heating system. Required fields are marked *, Ventilated Fire Stop Plates must be secured into the ceiling or the floor whenever the system exits and/or enters a habited space. I am aware there needs to be an air gap of 60mm from the flue pipe to any combiustibles. For each ceiling / joist you are to pass through, there are 3 essential components to purchase; 2 Ventilated Fire Stop Plates and a Joist Support. When using a 45 degree wall sleeve, should I pack it with Rockwool between the sleeve and the flue pipe, and leave a 60mm airgap around the outside of the sleeve. To shield the wooden walls from the heat of the stove and to allow us to site it 200mm from the sides of the stove into the corner of the shed, we initially installed some enamelled heat shields. Twin wall flue pipe cannot be cut to length by you to make it fit (although there are adjustable lengths) and one therefore needs to plan carefully when installing a twin wall flue chimney. This type of pipe has a second or third pipe running along the outside as shielding from the amount of heat that can pass through it. Please can someone advise me on this matter. From the top down you have liner, adaptor, vitreous 45 degree steel elbow, length of straight vitreous, another vitreous 45 elbow with a soot door to assist the sweep and at least 600mm of vertical that slots into the collar of your stove (sealed with fire cement). How to fit a wood burning or multifuel stove in a shed. Your email address will not be published. And finally, simply secure a Rain Cap, Anti-Wind Cowl or any choice of Twin Wall terminal available in your range of Twin Wall. Bare wood or sheetrock walls around a wood stove are fire hazards. The flue/stovepipe can also be where a damper can be found.I’ve explained everything you need to know about dampers here, but they can typically be found on older models of stove when the draw on the stove needs to be adjusted.. A damper is essentially a circular metal plate that sits inside the flue, with a handle that sticks out through the wall of the flue. Buy Flues for wood-burning and multi-fuel stoves, including flexible flue liner, single skin flues and insulated flues or twin wall flues. The sooner your gases hit a bend in the flue, the less able they will be to negotiate through it without depositing soot and possibly slumping back down the chimney so exiting the top outlet of the stove is ideal but you are allowed to exit the rear outlet via a Single Wall 90° Tee Piece if necessary. Make sure any self tappers do not protrude into the flue mure than 5mm so as not to hinder the sweep’s brushes. Radiating heat from the stove can pose a hazard to nearby walls and furniture, so wood stoves generally have a specified clearance - a minimum safe distance between the stove and nearby floors and walls. I have passed this on to our Customer Services Team who will respond to you directly and provide you with the advice needed. Due to the cleaner burning nature of these models, they alone are permitted to remain at 5” diameter for the entire flue system and still comply with Approved Document J of the Building Regulations. Installation depends on the route used for the vent pipes: vertical, horizontal, or a combination of both. Twin wall flue pipe is a “clip-together” chimney system that can be used to safely take the combustion gases from a wood burning stove and outside to the atmosphere. In our wood burning stoves, the flue collar is located on the top of the stoves, and can be seen just above the baffle. Thanks very much for your enquiry. The flue will have to rise at least 600mm above the highest point on the adjacent building. I would need to pass a twin-wall flue for the stove through a flat roof that covers a single storey section of the house. Wood stoves can get very, very hot during use. 61 sold. Wood-burning stoves keep your home warm and provide the added charm of flickering flames in the hearth. Which one should I be costing? Remember building regulations only allow for a maximum of 4 turns in the entire chimney and 2 have been occupied already (before and after passing through the wall), therefore you can only use 2 more elbows to create an offset around an obstacle, usually the gutters / soffits. First of all I must say that I have only installed a stove this way on two occasions and I do not have many pictures. So, my question is, will the pillar be thick (wide) enough ? Black stove pipe is used on the interior of the home from the top of the wood stove to the bottom of the ceiling or wall where it will connect to class-A chimney pipe or a masonry chimney thereafter. This rule is why you can never go horizontally straight through the wall into your chimney. You can cut steel vitreous flue pipe. what about roofelt how do you seal it to pipe. If you are installing a wood burning stove, boiler or gas appliance and you are planning to run your flue system either through a wall, a floor or externally you will need to use a twin wall flue system. I could I ‘move the window-frames along’ and have another brick-width on the side on the pillar that I will put the twin-walled pipe through and 1 brick-width less on the pillar by the house wall (which is already 1.5m wide). To exit the room & travel through the wall at 45 degrees takes about a metre so he is saying I can only move the flue about 0.4 metres in sideways direction. The picture on the left shows vitreous pipe passing through a hole in the wall. Again, this is due to hot gases needing to rise and if forced to travel horizontally, they shall lose their heat, deposit soot in the pipe and hit the right angle turn like a barrier and slump back down the system. 4) For internal systems passing up through the property, you shall require Joist Supports and Ventilated Fire Stop Plates for every ceiling the system passes through. Minimum clearance from combustible material: 450 mm (18 in.). The benefit of the Tee Piece & Cap is it allows essential access to the external run of flue for cleaning and draining of condensates and rain water. You can also use fire rope but you’ll use a lot of it. CAN RADIATING-TYPE WOOD STOVES EVER BE INSTALLED LESS THAN 36 INCHES FROM COMBUSTIBLES? Thanks for any suggestions. Regular gypsum plaster often cannot cope with the heat generated by a woodburner and may begin to crack or peel off, either almost immediately after the stove is lit or through gradual wear and tear. 100mm above the Flashing as an extra layer of protection against the elements. A flue pipe must never pass through a combustible floor or ceiling or through an attic, roof space, closet or concealed space. Chimney Register / Closure plate for Wood Burning Stoves & Flues Pipes. We are only concerned with the internal diameter of the system and so to maintain the same diameter throughout (i.e. I have passed this on to our Customer Services Team who will respond to you directly. And as the name suggests, the Joist Support screws to each joist and forms a bracket for the system roughly every 2.5m. The Sleeve protects both the pipe and the material of the wall from the thermal expansion of the pipe and the Plates tidy everything up inside and out. This is in place because the pipe will expand and contract with heat and either damage itself or break down the mortar around it (I have seen many done like this without protection). ... Black Twin Wall Multifuel Insulated Flue Pipe For Wood Burning Stove Convesa KC . I know from your site that I need to use a converter to connect twin-wall to my vertical pipe 4″ before I enter the wall. A twin wall flue pipe is a system, which can safely take combustion gases produced by a Wood Burning stove and release into the atmosphere. Running a Wood-Burning Stovepipe Out of a Wall. illegal to pass a single wall pipe through a wall, ceiling or roof, Approved Document J of the current Building Regulations, Vitreous Enamelled, Single-Wall Stove Pipe, 1200°C heat resistant cement or silicone sealant, Approved Document J of the Building Regulations, Glowing Embers Competition – WIN £200 M&S Vouchers, Cosy Up Your Garden Space This Winter with These Expert Tips, Installing Stoves – The Costs, Dangers, and Rise in Requests. Your first task will be to open up a hole in your chimney breast using a hammer drill on chisel function. Twin wall flue pipe has a 1 inch layer of insulation around the pipe. Have enough pipe so it … 1-1.5mm thickness. It really depends on which stove you are interested in and where you are installing. Wood Burning Stove Regulations ... except to pass directly into a chimney through either a wall of the chimney or a floor supporting the chimney. Any other thoughts ? Your hole will be a lot larger than ths (we had access to a hole in the outside wall in this case to connect our liner). From this point however, we are not heading through a wall but rather travelling up through the floors of a building to eventually exit through the roof surface. The first common error made when installing a wood burning stove chimney through a wall is that you can exit out from the rear of the stove and run horizontally, directly through the wall to the outside. It is possible to skip this step and connect the Twin Wall flue directly to the outlet collar with an Adapter however, this may over time tarnish the finish of a stainless Twin Wall pipe or remove the coating entirely from a black Twin Wall pipe. You are here because you wish to connect your stove to a flexible chimney liner but you are NOT inserting your stove into a fireplace recess (builder’s opening). A flue pipe must never pass through a combustible floor or ceiling or through an attic, roof space, closet or concealed space. Today's wood stoves burn efficiently and pollute less, but any heat source can be a fire hazard if it isn't installed properly. Instead of going thru my roof overhang can I angle out to the edge of the overhang then up the rest of the way? The hole needs to be at a sufficient height to ensure your stove plus a minimum 600mm stove pipe can be acommodated. No matter the flue system you are going to create, they should all begin with a length of Vitreous Enamelled, Single-Wall Stove Pipe. How will Eco Design 2022 Regulations affect me. Your stove clearance can depend on where you live, whether your … If you do not have an existing chimney in your home to install a wood burning stove into, a new class 1 chimney system needs to be created using Twin Wall (or Double Skin) insulated flue pipes. ... relining work comprising the creation of new flue walls by the insertion of new linings such as rigid or flexible prefabricated components. However, it is for this very reason that it is unsafe and even illegal to pass a single wall pipe through a wall, ceiling or roof as the outer surface will become far too hot and may transfer that heat into nearby combustible materials such as joists and furnishings. For an external Twin Wall system rising up any wall other than a gable end, you must consider two building regulation requirements: If rising up a gable end, the above still applies but with one caveat: A couple of additional points that often occur concern adjacent buildings and dormer windows: a) If the system looks due to terminate below a window in a pitched roof or within 2.3m horizontally of any openable window, sun light or dormer, then you must extend the system 1000mm above the window, b) Any adjacent buildings within 2.3m of your flue system must unfortunately also be cleared. This twin wall flue systems can also be used with gas or oil appliances. Twin wall flue pipe systems are designed to keep the flue gases warm. i.e. Radiating heat from the stove can pose a hazard to nearby walls and furniture, so wood stoves generally have a specified clearance - a minimum safe distance between the stove and nearby floors and walls. of flues and chimneys for wood burning and multi fuel appliances in residential properties. This is incorrect as there must be no horizontal runs totalling greater than 150mm in length in a flue system or 90° (right angle) turns. The picture on the left shows vitreous pipe passing through a hole in the wall. You will use your upper hole to connect your adaptor to your liner and your first elbow to your adaptor (with a couple of self tappers. DuraVent - Duraplus 6 in. Stovepipe differs from chimney systems. No matter which type of system is being installed, any joints between pipes must be accessible and not buried within walls or joists and the Twin Wall must be boxed or caged in on the upper floors. Please take this very seriously the thin blades can shatter. Fitting a stove in a shed or summerhouse needn’t be complicated if a few basic rules are followed. Final note: It is important to note that whilst wood burning and multi-fuel stove installations are NOT covered by building regulations on structures that are not considered “habitable”, safety is still an important consideration.Our network of retailers are best qualified to offer you the knowledge of our product ranges and the installation requirements needed when choosing an Arada stove. The 45° Elbow does not offer this access. Im costing to install a Hwam 2360 in my bungalow with a top mounted flue direct up (no bends). The flue/stovepipe can also be where a damper can be found.I’ve explained everything you need to know about dampers here, but they can typically be found on older models of stove when the draw on the stove needs to be adjusted.. A damper is essentially a circular metal plate that sits inside the flue, with a handle that sticks out through the wall of the flue. It is a common misconception that a system increases when it converts from Single Wall to Twin Wall flue simply due to the change in the overall size of the pipe but this is incorrect. YOU CAN ONLY CUT THE FEMALE END OF ANY VITREOUS STEEL PIPE (THE TOP OF EACH PIECE). DG IVAR 5 DELIVERY DUE THIS WEEK! Proper sealing is very important to ensure that heat exhaust is vented out of the home and not collecting inside the home or on the heating system. It is not made to pass through walls and does not have proper … This is because hot gases only want to rise and every turn or not vertical section of the flue is a hinderence or obstruction to that. You will need to match your stove pipe diameter with the diameter of the flue size on your wood burning stove. This twin wall flue systems can also be used with gas or oil appliances. Twin wall insulated flue is suitable for constructing internal and external flue systems for wood burning stoves, multifuel stoves, gas and high temperature oil stoves. Twin Wall Flue by Flue Direct, the leading UK supplier of HETAS approved flues; twin wall flue pipe, flexible flue liner and all other flue products for log burners, multi fuel stoves, wood burning stoves, fires, commercial and biomass boilers. Our twinwall flue pipe is a double skinned flue that is approved by the latest HETAS official guide for approved solid fuel products. And if gases are not rising, they are colling, losing their power and depositing soot etc within the system. Quick Step Guide to Non-Chimney Installations 1) Start your system with a length of Single Wall, Vitreous Enamel Stove Pipe in the same diameter as the outlet on the stove. It is conventional to install wall shields over fire-resistant wall spacers. Wood-burning stoves keep your home warm and provide the added charm of flickering flames in the hearth. This guide has been produced by the BFCMA to provide advice and general guidance on the selection and installation of chimneys and flues for maximum performance, safety and durability. For the optimum draw on your stove and compliance with the building regulations, the overall length of your flue system must attain a minimum length of 4.5m from stove outlet to Rain Cap. Note that I have protected the flue pipe with fireproof webbing (sticky back). Have enough pipe so it … Hi Another 45° Elbow or Tee Piece can be connected once through the wall to turn the system vertically. 58 sold. The minimum clearance may be reduced by 50 percent to 225 mm (9 in.) A fire-resistant wall shield is necessary to eliminate the threat of fire. However, if there is no alternative, the stove pipe must be passed through a thimble or collar. Minimum clearance from combustible material: 450 mm (18 in.). I use masking tape to get a perfect line and then carefully cut all the way round. The diameter of the outlet collar is the minimum diameter for the entire flue system and you can never reduce this. TEXT 07520635388 IS FASTEST. Basically, this boils down to requiring these plates everywhere except for the floor of the attic but even there it is recommended. And the male, narrow spigot must only be at the bottom of the pipe and not the other way around, no matter if it seems to fit better upside down as you will not be able to connect your Single to Twin Wall Adapter to the wrong end. The Flashing itself is a silicone or EPDM rubber cone that sits atop a base (traditionally lead but more likely aluminium these days) and can be cut back to tightly grip around the flue to provide a weather proof seal on the roof. 8) Once through the roof Surface (internal) or past the roof/gutter line (external), Twin Wall systems must attain a minimum vertical height of 1m to create a minimum horizontal clearance of 2.3m. the stove pipe elbows. You will have to make a larger hole in the wall than I did or have another hole on the other side of the chimney (we had access to the outside wall of the property). Purchase double-wall or triple-wall pipe for a wood stove. The hot flue gases from your stove need to be able to discharge freely and not present a fire hazard, whatever the wind conditions. Yes. Or build a heat shield to be mounted 1 inch off the wall on non-combustible spacers. A typical internal Twin Wall flue system starts identically to that of an external system from the stove collar to the Twin Wall Adapter, as outlined above. Also important to bear in mind; hot gases want to rise and therefore a straight vertical length at the start of the system encourages this. One aspect of wood-burning stove installation that can be overlooked is the nearby walls and, in particular, the plaster on those walls. I have a brick built fireplace where the log burner will be installed but i need to pass the vitreous pipe through the internal brick skin (behind the log burner) then a 100mm cavity and a 100mm dense concrete block at an angle of 45 degrees the vitreous pipe will then connect to a twin wall pipe in a new built chimney (this is where the register plate will be) . I see many flues outside at 2 metres with similar height. That measurement is indeed along the 45 degree line (NO horizontals are permitted) and just because you see other flues like that, does not mean they are safe, legal or working well. To comply with the building regulations, a 90° Tee Piece (or elbow) can only be used directly in the rear outlet of the stove and absolutely nowhere else in the system. This is only applicable for passing through standard, non-combustible cavity walls. Observe your stove's clearance rating when picking a suitable spot. There are two important points to consider when calculating the lengths of Twin Wall flue required to successfully (and legally) run the system up the outside of your property wall; 1) the overall height of the finished flue 2) do you need to negotiate around any obstacles such as windows or overhanging soffits? The minimum internal diameter for a flue system when you reach the Twin Wall section is 6” (150mm) and this is easily attained by selecting the correct Single to Twin Wall Adapter. if suitable shielding is installed either on the pipe or on the combustible surface. 320mm across (60mm clearance + 200mm outer diameter of pipe + 60mm clearance). Wood Stove Installation Step 4 - Stove Pipe. Twin wall flue pipe is a “clip-together” chimney system that can be used to safely take the combustion gases from a wood burning stove and outside to the atmosphere. You should not pass a stove pipe through a combustible wall for a hook-up with a chimney flue. Then you will add your next piece of steel vitreous and so on (using self tappers to connect each). In order to do that you need a chimney with a good draw. Budget stoves; Balanced flue gas stoves; Defra approved stoves; Designer wood burning stoves; Double sided Multi-fuel and wood stoves; Electric stoves; Flue-less gas stoves Can a Triple Wall Flue Pipe Be Used for a Wood Stove?. Wood Stove Installation Step 4 - Stove Pipe. Simply seal this connection with at least 1200°C heat resistant cement or silicone sealant. It is conventional to install wall shields over fire-resistant wall spacers. Your hole will be a lot larger than ths (we had access to a hole in the outside wall in this case to connect our liner). You are permitted a maximum of 4 turns in any one flue system and typically as far as an external Twin Wall flue system is concerned, these would be used 1 inside and 3 outside; 1 to turn the sytem vertically and 2 to negotiate around guttering or soffits etc. 6) Joist Supports are sufficient for supporting an internal system with Adjustable Wall Brackets providing the support for an external system every 2m maximum. Free postage. 25mm compressed rockwool insulation. Check with a store that specializes in wood burning stoves. Thirdly, combine your Flashing with a Twin Wall Storm Collar to sit approx. However, it may require more work to fit one than in an existing chimney. they can tell you exactly the type and size of the of the venting materials required. The “long nose adaptor with bolts” connects to the liner with three bolts and is self explanatory when you see it (some you need to self tapper to the liner but I like the bolt versions).
Maytag Washer Not Spinning, Bird Scooter Logo Png, Historical Home Loan Interest Rates Australia, Mythbusters Shark Magnets, How Many Cucumbers In A Quart, Wisteria Macrostachya 'aunt Dee, Mtg Vintage Vs Legacy,